FALAD POWER generator sets lined up in the factory warehouse

Diesel Generator Sets Powered by Volvo Penta

100–750 kVA

  • CE / ISO
  • Certified OEM Factory
  • Global Warranty
Get a Quote

In-House Manufacturing

Our own production base covers genset R&D, manufacturing, assembly and testing under one roof.

Global Export

Shipped to 80+ countries, with experience in import regulations, port logistics and local certification.

Full-Load Testing

Every unit is load-tested before dispatch and ships with a detailed test report.

OEM

OEM Customization

Custom branding, canopy, configuration and functions — a one-stop OEM genset service.

Overview

Volvo Penta supplies industrial power generation engines for standby and project power applications. This page features FALAD POWER generator sets powered by Volvo Penta engines. Share your required power, voltage, frequency and destination to request a configuration and quote.

Select power (50 Hz) 23 models

Volvo Penta

Volvo Penta – China Stage III/IV

Genset model: YXWEW160GF
Engine BrandVolvo Penta
Engine ModelTAD840GE
Generator Set Prime Power (PRP)160 kW / 200 kVA
Generator Set Standby Power (ESP)180 kW / 225 kVA
Frequency / Rated Speed50 Hz / 1500 rpm
Fuel Consumption at 100% Load208 g/kWh
Overall Dimensions (L×W×H)2600 × 1060 × 1530 mm
Total Weight1,850 kg

Brand Introduction

Volvo Penta engine manufacturing

Volvo Penta is a well-known Swedish power brand founded in 1907. Its established industrial engine technology serves industrial equipment and power generation applications.

Core advantages

  • Established engineering technology
  • Reliable power output
  • A diverse product range
  • Industrial application experience
  • Flexible power configurations
  • 1907Founded
  • SwedenOrigin
  • GothenburgHeadquarters

Technical Parameters

Volvo Penta

Volvo Penta technical parameters, 50 Hz / 1500 rpm
Genset ModelPrime Power (kW / kVA)Standby Power (kW / kVA)Engine ModelDimensions L×W×H (mm)Weight (kg)
160 / 200 180 / 225 TAD840GE 2600×1060×1530 1,850
200 / 250 220 / 275 TAD841GE 2600×1060×1530 1,850
250 / 312.5 275 / 343.8 TAD843GE 2910×1200×1700 2,650
280 / 350 300 / 375 TAD1342GE-B 2910×1200×1700 2,730
300 / 375 330 / 412.5 TAD1343GE-B 3000×1200×1700 2,800
320 / 400 350 / 437.5 TAD1344GE-B 3100×1120×1600 3,050
360 / 450 400 / 500 TAD1345GE-B 3150×1120×1885 3,270
400 / 500 440 / 550 TAD1346GE-B 3400×1120×1885 3,780
450 / 562.5 500 / 625 TAD1642GE-B 3400×1120×1885 3,780

Volvo Penta – China Stage III/IV

Volvo Penta – China Stage III/IV technical parameters, 50 Hz / 1500 rpm
Genset ModelPrime Power (kW / kVA)Standby Power (kW / kVA)Engine ModelDimensions L×W×H (mm)Weight (kg)
80 / 100 90 / 112.5 TAD580VE 2600×1060×1530 1,850
100 / 125 110 / 137.5 TAD582VE 2600×1060×1530 1,850
120 / 150 132 / 165 TAD880VE 2910×1200×1700 2,650
150 / 187.5 165 / 206.3 TAD882VE 2910×1200×1700 2,650
200 / 250 220 / 275 TAD851GE 2600×1060×1530 1,850
250 / 312.5 275 / 343.8 TAD1351GE 2910×1200×1700 2,650
300 / 375 330 / 412.5 TAD1354GE 3250×1120×1885 3,780
320 / 400 350 / 437.5 TAD1355GE 3250×1120×1885 3,780
360 / 450 400 / 500 TAD1650GE 3400×1120×1885 3,780
400 / 500 450 / 562.5 TAD1651GE 3400×1120×1885 3,780
450 / 562.5 500 / 625 TWD1652GE 3500×1120×1885 4,000
500 / 625 550 / 687.5 TWD1653GE 3500×1120×1885 4,000
550 / 687.5 600 / 750 TWD1645GE 3500×1120×1885 4,000
600 / 750 660 / 825 TWD1744GE 3500×1120×1885 4,000

Data at 50 Hz, 1500 rpm, 400 V, 0.8 power factor (lagging), three-phase four-wire. 60 Hz ratings, other voltages and custom configurations are available — ask for a full datasheet.

Product Advantages & Core Configuration

Factory tested
  • Diesel engine for a generator set

    Officially Authorized

    Genuine engines from multiple brands

  • Generator set digital controller

    Intelligent Protection

    Remote monitoring and control

  • Brushless alternator

    Flexible Options

    Configured to your requirements

Accessories

  • Branded electrical components, switches and meters

    Branded Electrical Components

  • Maintenance-free starter battery

    Camel / VARTA Maintenance-Free Battery

  • Cloud remote monitoring module

    Cloud Monitoring Module

  • Engine oil and water jacket heater

    Oil & Water Jacket Heater

Weifang Yuxing Power Co., Ltd. manufacturing base of FALAD POWER generator sets in Weifang, Shandong

Why Choose Us

  • Industry Experience

    Proven genset R&D and manufacturing expertise, with project references worldwide.

  • Global Supply

    Exported to many countries; we know local standards and supply reliably.

  • Strict Testing

    Every set is inspected and run-tested for stable, long-term operation.

  • Flexible Configuration

    Engine, alternator and controller brands are combined to suit each application.

  • Fast Response

    A mature production line and supply chain ensure on-time delivery and lower project risk.

  • Technical Support

    Sizing, installation, commissioning and after-sales technical support.

Generator production workshop

300,000+

Total units sold

Aerial view of the factory campus

60,449 m²

Factory area

Factory building exterior

8,000+

Partner service points

Intelligent generator test center

Full-load

Test report for every unit

From Our Factory to Your Site

  • Gas generator sets running a biogas power project

    Biogas Projects

  • Containerized power station at an oil field

    Oil & Gas Fields

  • Natural gas generator containers in a row

    Natural Gas Projects

  • Generator set at a remote telecom tower

    Telecom Base Stations

  • Generator being installed on a construction site

    Construction

  • Standby diesel generators in a data center

    Data Centers

  • Engineers commissioning hospital backup power panels

    Hospital Backup Power

  • Alternator assembly workshop

    Alternator Assembly Workshop

  • Diesel genset assembly workshop

    Genset Assembly Workshop

  • Silent generator sets for factory standby power

    Factory Standby Power

  • Trailer generator sets for a mining project

    Mining Projects

  • Generator sets loaded on a truck for delivery

    Project Logistics

Brand Partners

Engine partners

  • Perkins logoPerkins
  • Cummins logoCummins
  • Volvo Penta logoVolvo Penta
  • DEUTZ logoDEUTZ
  • Scania logoScania
  • FPT logoFPT
  • Isuzu logoIsuzu
  • MTU logoMTU
  • Kubota logoKubota
  • Hyundai (Doosan) logoHyundai (Doosan)
  • Baudouin logoBaudouin
  • Weichai logoWeichai
  • Yuchai logoYuchai
  • SDEC logoSDEC
  • FAWDE logoFAWDE
  • Yunnei logoYunnei
  • Yangdong logoYangdong
  • YUXING logo – Weifang Yuxing Power Co., Ltd.YUXING

Alternator partners

  • Stamford logoStamford
  • Leroy-Somer logoLeroy-Somer
  • Mecc Alte logoMecc Alte
  • Engga logoEngga
  • FALAD POWER® (Faraday) alternator – own brand of Shandong Faraday Power Technology Co., Ltd.FALAD POWER®

Controller partners

  • ComAp logoComAp
  • DSE logoDSE
  • DEIF logoDEIF
  • SmartGen logoSmartGen
  • FALAD POWER® controller – own brand of Shandong Faraday Power Technology Co., Ltd.FALAD POWER®

FAQ

How do I size a diesel or gas generator set, and what power range does FALAD POWER® manufacture?

To size a generator set, check the running load and the motor-starting condition separately: work out the total load at the moment your largest motor starts in consistent units, and choose a set whose rating and motor-starting capability cover it (VFD, soft-starter or Star-Delta starting lowers the starting demand). Allow a 20–25% reserve margin and account for site altitude (>1,000 m) and ambient temperature (>40 °C) derating per ISO 8528-1; our engineers confirm the calculation for your load list. Shandong Faraday Power Technology Co., Ltd. (FALAD POWER®) manufactures over 1,700 models covering 10–3750 kVA at 50 Hz (1500 rpm, 400/230 V up to 10.5 kV) and 60 Hz (1800 rpm, 208–480 V up to 13.8 kV). Send us your load list or single-line diagram for a free engineering sizing report.

What is the difference between Prime Power, Standby Power and Continuous Power?

ISO 8528-1 defines four ratings:
• Continuous Power (COP): constant load, unlimited running hours — for base-load plants running the same load around the clock.
• Prime Power (PRP): variable load, unlimited annual hours, average load no more than 70% over 24 hours, with 10% overload typically available for 1 hour in every 12 — for mines, construction sites and areas without grid power.
• Limited-Time Running Power (LTP): constant load for up to 500 hours a year, no overload.
• Emergency Standby Power (ESP): variable load during grid outages only, typically up to 200 hours a year, no overload — for hospitals, offices, data centers and factories that need grid backup.
Standby rating is about 10% higher than prime (for example, 500 kVA prime ≈ 550 kVA standby). Every FALAD POWER datasheet lists both prime and standby ratings. Tell us whether the set will be your main power source or a grid backup, and we will quote the right rating. All sets use pure copper brushless alternators from Stamford, Leroy-Somer, Mecc Alte, Marathon, Engga or FALAD POWER.

Get a Quote

I would like

* Please provide either your Email address or WhatsApp number so our engineers can send your quotation within 24 hours.

We reply within 24 hours. Your details are used only to answer your enquiry – see our Privacy Policy.

WhatsApp Email Get a Quote