FALAD POWER generator sets lined up in the factory warehouse

Diesel Generator Sets Powered by Perkins

10–2500 kVA

  • CE / ISO
  • Certified OEM Factory
  • Global Warranty
Get a Quote

In-House Manufacturing

Our own production base covers genset R&D, manufacturing, assembly and testing under one roof.

Global Export

Shipped to 80+ countries, with experience in import regulations, port logistics and local certification.

Full-Load Testing

Every unit is load-tested before dispatch and ships with a detailed test report.

OEM

OEM Customization

Custom branding, canopy, configuration and functions — a one-stop OEM genset service.

Overview

Perkins is a diesel engine brand with products for power generation and other industrial equipment. This page features FALAD POWER generator sets powered by Perkins engines. Share your required power, voltage, frequency and destination to request a configuration and quote.

Select power (50 Hz) 36 models

Genset model: YXPJS8GF
Engine BrandPerkins
Engine Model403D-11G
Generator Set Prime Power (PRP)8 kW / 10 kVA
Generator Set Standby Power (ESP)9 kW / 11.3 kVA
Frequency / Rated Speed50 Hz / 1500 rpm
Fuel Consumption at 100% Load248 g/kWh
Overall Dimensions (L×W×H)1580 × 810 × 930 mm
Total Weight380 kg

Brand Introduction

Perkins engine manufacturing

Perkins is a long-established, large-scale diesel engine supplier committed to products and services that exceed customer expectations. Founded in 1932, it has produced more than 21 million engines for over 5,000 applications worldwide. Its business spans 176 countries and regions, with more than 3,500 outlets.

Core advantages

  • A long-established brand
  • A broad product range
  • A broad power range
  • OEM integration experience
  • A global service network
  • 1932Founded
  • GlobalParts network

Technical Parameters

Perkins technical parameters, 50 Hz / 1500 rpm
Genset ModelPrime Power (kW / kVA)Standby Power (kW / kVA)Engine ModelDimensions L×W×H (mm)Weight (kg)
8 / 10 9 / 11.3 403D-11G 1580×810×930 380
10 / 12.5 11 / 13.8 403A-15G2 1580×810×930 540
16 / 20 18 / 22.5 404A-22G 1580×810×990 540
20 / 25 22 / 27.5 1103A-33G 1580×810×1165 660
24 / 30 26 / 32.5 1103A-33G 1580×810×1165 660
30 / 37.5 33 / 41.3 1103A-33TG1 1595×810×1150 730
36 / 45 40 / 50 1103A-33TG1 1595×810×1150 730
50 / 62.5 55 / 68.8 1104A-44TG1 1760×810×1165 780
64 / 80 70 / 87.5 1104A-44TG2 1760×810×1165 800
80 / 100 90 / 112.5 1104C-44TAG2 2240×960×1315 1,030
100 / 125 110 / 137.5 1106A-70TG1 2240×960×1315 1,030
120 / 150 132 / 165 1106A-70TAG2 2240×960×1315 1,300
150 / 187.5 170 / 212.5 1106A-70TAG3 2345×810×1365 1,300
160 / 200 180 / 225 1106A-70TAG4 2240×960×1590 1,300
180 / 225 200 / 250 1206A-E70TTAG2 2430×960×1590 2,170
200 / 250 220 / 275 1206A-E70TTAG3 2430×960×1590 2,170
250 / 312.5 280 / 350 1706A-E93TAG1 3030×1120×1800 2,500
280 / 350 300 / 375 2206C-E13TAG2 3030×1120×1800 2,500
300 / 375 330 / 412.5 2206C-E13TAG3 3030×1120×1800 2,500
320 / 400 350 / 437.5 2206C-E13TAG3 3030×1120×1800 2,500
360 / 450 400 / 500 2506C-E15TAG1 3280×1130×1950 3,800
400 / 500 440 / 550 2506C-E15TAG2 3310×1180×1950 3,940
480 / 600 530 / 662.5 2806C-E18TAG1A 3310×1180×1950 3,940
500 / 625 550 / 687.5 2806A-E18TAG2 3310×1180×1950 3,940
600 / 750 660 / 825 4006-23TAG3A 4450×1750×2350 4,700
640 / 800 700 / 875 4006-23TAG3A 4450×1750×2350 4,700
730 / 912.5 800 / 1000 4008TAG1A 4850×1870×2350 7,600
800 / 1000 900 / 1125 4008TAG2 4850×1870×2350 7,600
900 / 1125 1000 / 1250 4008-30TAG3 4850×1995×2330 7,600
1000 / 1250 1100 / 1375 4012-46TWG2A 4900×1860×2350 9,160
1200 / 1500 1300 / 1625 4012-46TAG2A 4900×1860×2350 11,580
1400 / 1750 1550 / 1937.5 4012-46TAG3A 4900×1860×2350 11,580
1500 / 1875 1650 / 2062.5 4016TAG1A 6800×2780×3500 12,000
1600 / 2000 1800 / 2250 4016TAG2A 6800×2780×3500 12,000
1800 / 2250 2000 / 2500 4016-61TRG3 8000×3120×4400 13,400
2000 / 2500 2200 / 2750 4016-61TRG3X 8000×3120×4400 13,400

Data at 50 Hz, 1500 rpm, 400 V, 0.8 power factor (lagging), three-phase four-wire. 60 Hz ratings, other voltages and custom configurations are available — ask for a full datasheet.

Product Advantages & Core Configuration

Factory tested
  • Diesel engine for a generator set

    Officially Authorized

    Genuine engines from multiple brands

  • Generator set digital controller

    Intelligent Protection

    Remote monitoring and control

  • Brushless alternator

    Flexible Options

    Configured to your requirements

Accessories

  • Branded electrical components, switches and meters

    Branded Electrical Components

  • Maintenance-free starter battery

    Camel / VARTA Maintenance-Free Battery

  • Cloud remote monitoring module

    Cloud Monitoring Module

  • Engine oil and water jacket heater

    Oil & Water Jacket Heater

Weifang Yuxing Power Co., Ltd. manufacturing base of FALAD POWER generator sets in Weifang, Shandong

Why Choose Us

  • Industry Experience

    Proven genset R&D and manufacturing expertise, with project references worldwide.

  • Global Supply

    Exported to many countries; we know local standards and supply reliably.

  • Strict Testing

    Every set is inspected and run-tested for stable, long-term operation.

  • Flexible Configuration

    Engine, alternator and controller brands are combined to suit each application.

  • Fast Response

    A mature production line and supply chain ensure on-time delivery and lower project risk.

  • Technical Support

    Sizing, installation, commissioning and after-sales technical support.

Generator production workshop

300,000+

Total units sold

Aerial view of the factory campus

60,449 m²

Factory area

Factory building exterior

8,000+

Partner service points

Intelligent generator test center

Full-load

Test report for every unit

From Our Factory to Your Site

  • Gas generator sets running a biogas power project

    Biogas Projects

  • Containerized power station at an oil field

    Oil & Gas Fields

  • Natural gas generator containers in a row

    Natural Gas Projects

  • Generator set at a remote telecom tower

    Telecom Base Stations

  • Generator being installed on a construction site

    Construction

  • Standby diesel generators in a data center

    Data Centers

  • Engineers commissioning hospital backup power panels

    Hospital Backup Power

  • Alternator assembly workshop

    Alternator Assembly Workshop

  • Diesel genset assembly workshop

    Genset Assembly Workshop

  • Silent generator sets for factory standby power

    Factory Standby Power

  • Trailer generator sets for a mining project

    Mining Projects

  • Generator sets loaded on a truck for delivery

    Project Logistics

Brand Partners

Engine partners

  • Perkins logoPerkins
  • Cummins logoCummins
  • Volvo Penta logoVolvo Penta
  • DEUTZ logoDEUTZ
  • Scania logoScania
  • FPT logoFPT
  • Isuzu logoIsuzu
  • MTU logoMTU
  • Kubota logoKubota
  • Hyundai (Doosan) logoHyundai (Doosan)
  • Baudouin logoBaudouin
  • Weichai logoWeichai
  • Yuchai logoYuchai
  • SDEC logoSDEC
  • FAWDE logoFAWDE
  • Yunnei logoYunnei
  • Yangdong logoYangdong
  • YUXING logo – Weifang Yuxing Power Co., Ltd.YUXING

Alternator partners

  • Stamford logoStamford
  • Leroy-Somer logoLeroy-Somer
  • Mecc Alte logoMecc Alte
  • Engga logoEngga
  • FALAD POWER® (Faraday) alternator – own brand of Shandong Faraday Power Technology Co., Ltd.FALAD POWER®

Controller partners

  • ComAp logoComAp
  • DSE logoDSE
  • DEIF logoDEIF
  • SmartGen logoSmartGen
  • FALAD POWER® controller – own brand of Shandong Faraday Power Technology Co., Ltd.FALAD POWER®

FAQ

How do I size a diesel or gas generator set, and what power range does FALAD POWER® manufacture?

To size a generator set, check the running load and the motor-starting condition separately: work out the total load at the moment your largest motor starts in consistent units, and choose a set whose rating and motor-starting capability cover it (VFD, soft-starter or Star-Delta starting lowers the starting demand). Allow a 20–25% reserve margin and account for site altitude (>1,000 m) and ambient temperature (>40 °C) derating per ISO 8528-1; our engineers confirm the calculation for your load list. Shandong Faraday Power Technology Co., Ltd. (FALAD POWER®) manufactures over 1,700 models covering 10–3750 kVA at 50 Hz (1500 rpm, 400/230 V up to 10.5 kV) and 60 Hz (1800 rpm, 208–480 V up to 13.8 kV). Send us your load list or single-line diagram for a free engineering sizing report.

What is the difference between Prime Power, Standby Power and Continuous Power?

ISO 8528-1 defines four ratings:
• Continuous Power (COP): constant load, unlimited running hours — for base-load plants running the same load around the clock.
• Prime Power (PRP): variable load, unlimited annual hours, average load no more than 70% over 24 hours, with 10% overload typically available for 1 hour in every 12 — for mines, construction sites and areas without grid power.
• Limited-Time Running Power (LTP): constant load for up to 500 hours a year, no overload.
• Emergency Standby Power (ESP): variable load during grid outages only, typically up to 200 hours a year, no overload — for hospitals, offices, data centers and factories that need grid backup.
Standby rating is about 10% higher than prime (for example, 500 kVA prime ≈ 550 kVA standby). Every FALAD POWER datasheet lists both prime and standby ratings. Tell us whether the set will be your main power source or a grid backup, and we will quote the right rating. All sets use pure copper brushless alternators from Stamford, Leroy-Somer, Mecc Alte, Marathon, Engga or FALAD POWER.

Get a Quote

I would like

* Please provide either your Email address or WhatsApp number so our engineers can send your quotation within 24 hours.

We reply within 24 hours. Your details are used only to answer your enquiry – see our Privacy Policy.

WhatsApp Email Get a Quote