Diesel Generator Sets Powered by DEUTZ
23–750 kVA
- CE / ISO
- Certified OEM Factory
- Global Warranty
In-House Manufacturing
Our own production base covers genset R&D, manufacturing, assembly and testing under one roof.
Global Export
Shipped to 80+ countries, with experience in import regulations, port logistics and local certification.
Full-Load Testing
Every unit is load-tested before dispatch and ships with a detailed test report.
OEM Customization
Custom branding, canopy, configuration and functions — a one-stop OEM genset service.
Overview
DEUTZ is a German engine brand with industrial and power generation applications. This page features FALAD POWER generator sets powered by DEUTZ engines. Share your required power, voltage, frequency and destination to request a configuration and quote.
Select power (50 Hz) 26 models
| Engine Brand | DEUTZ |
|---|---|
| Engine Model | BFM3G3 |
| Generator Set Prime Power (PRP) | 18 kW / 22.5 kVA |
| Generator Set Standby Power (ESP) | 20 kW / 25 kVA |
| Frequency / Rated Speed | 50 Hz / 1500 rpm |
| Fuel Consumption at 100% Load | 228 g/kWh |
| Overall Dimensions (L×W×H) | 1610 × 950 × 1050 mm |
| Total Weight | 560 kg |
Brand Introduction

SINCE 1864
Founded in 1864, DEUTZ has five production sites, 13 sales companies, seven sales offices, 16 service centers and 800 sales and service partners across more than 130 countries.
Core advantages
- German engineering heritage
- Turbocharging technology
- Engine structural design
- Multiple power configurations
- Industrial application experience
- 1864Founded
- CompactDiesel engines
Technical Parameters
| Genset Model | Prime Power (kW / kVA) | Standby Power (kW / kVA) | Engine Model | Dimensions L×W×H (mm) | Weight (kg) |
|---|---|---|---|---|---|
| 18 / 22.5 | 20 / 25 | BFM3G3 | 1610×950×1050 | 560 | |
| 20 / 25 | 26 / 32.5 | BFM3G4 | 1610×950×1050 | 595 | |
| 24 / 30 | 26 / 32.5 | BFM3TG1 | 1610×950×1050 | 595 | |
| 36 / 45 | 40 / 50 | BFM3TG2 | 1995×950×1085 | 830 | |
| 40 / 50 | 45 / 56.3 | BFM3CG1 | 1995×950×1085 | 830 | |
| 50 / 62.5 | 55 / 68.8 | BF4M2012 | 1955×950×1360 | 995 | |
| 60 / 75 | 66 / 82.5 | BF4M2012C G1 | 2195×1050×1265 | 1,180 | |
| 75 / 93.8 | 83 / 103.8 | BF4M2012C G2 | 2195×1050×1265 | 1,225 | |
| 80 / 100 | 88 / 110 | BF4M1013EC G1 | 2395×1050×1542 | 1,335 | |
| 90 / 112.5 | 100 / 125 | BF4M1013EC G2 | 2395×1050×1542 | 1,335 | |
| 90 / 112.5 | 100 / 125 | F8L413F | 2700×1450×1950 | 1,665 | |
| 100 / 125 | 110 / 137.5 | BF4M1013FC | 2395×1000×1410 | 1,350 | |
| 120 / 150 | 132 / 165 | BF8L513 | 2700×1450×1950 | 1,715 | |
| 120 / 150 | 132 / 165 | BF6M1013EC G1 | 2550×1150×1560 | 1,665 | |
| 150 / 187.5 | 165 / 206.3 | BF8L513C | 2700×1450×1950 | 1,715 | |
| 150 / 187.5 | 165 / 206.3 | BF6M1013FC G2 | 2550×1250×1700 | 1,980 | |
| 160 / 200 | 180 / 225 | BF6M1013FC G3 | 2550×1250×1700 | 2,030 | |
| 200 / 250 | 220 / 275 | TCD8.0 | 2550×1250×1700 | 2,030 | |
| 250 / 312.5 | 280 / 350 | BF6M1015C-LA G3A | 2800×1450×1950 | 3,100 | |
| 280 / 350 | 300 / 375 | BF6M1015C-LA G4 | 2800×1450×1950 | 3,100 | |
| 300 / 375 | 330 / 412.5 | BF6M1015CP-LAG | 2800×1450×1950 | 3,100 | |
| 360 / 450 | 400 / 500 | TCD13.0 G1 | 3300×1240×1855 | 3,200 | |
| 400 / 500 | 440 / 550 | TCD13.0 G2 | 3300×1240×1855 | 3,200 | |
| 500 / 625 | 550 / 687.5 | D17 | 3900×1750×2300 | 4,900 | |
| 550 / 687.5 | 605 / 756.3 | HC12V132ZL-LAG1A | 4350×1750×2200 | 5,000 | |
| 600 / 750 | 660 / 825 | HC12V132ZL-LAG2A | 4350×1750×2200 | 5,000 |
Data at 50 Hz, 1500 rpm, 400 V, 0.8 power factor (lagging), three-phase four-wire. 60 Hz ratings, other voltages and custom configurations are available — ask for a full datasheet.
Product Advantages & Core Configuration
Factory tested
Officially Authorized
Genuine engines from multiple brands

Intelligent Protection
Remote monitoring and control

Flexible Options
Configured to your requirements
Accessories

Branded Electrical Components

Camel / VARTA Maintenance-Free Battery

Cloud Monitoring Module

Oil & Water Jacket Heater

Why Choose Us
-
Industry Experience
Proven genset R&D and manufacturing expertise, with project references worldwide.
-
Global Supply
Exported to many countries; we know local standards and supply reliably.
-
Strict Testing
Every set is inspected and run-tested for stable, long-term operation.
-
Flexible Configuration
Engine, alternator and controller brands are combined to suit each application.
-
Fast Response
A mature production line and supply chain ensure on-time delivery and lower project risk.
-
Technical Support
Sizing, installation, commissioning and after-sales technical support.
300,000+
Total units sold
60,449 m²
Factory area
8,000+
Partner service points
Full-load
Test report for every unit
From Our Factory to Your Site
-
Biogas Projects
-
Oil & Gas Fields
-
Natural Gas Projects
-
Telecom Base Stations
-
Construction
-
Data Centers
-
Hospital Backup Power
-
Alternator Assembly Workshop
-
Genset Assembly Workshop
-
Factory Standby Power
-
Mining Projects
-
Project Logistics
Brand Partners
Engine partners
Perkins
Cummins
Volvo Penta
DEUTZ
Scania
FPT
Isuzu
MTU
Kubota
Hyundai (Doosan)
Baudouin
Weichai
Yuchai
SDEC
FAWDE
Yunnei
Yangdong
YUXING
Alternator partners
Stamford
Leroy-Somer
Mecc Alte
Engga
FALAD POWER®
Controller partners
ComAp
DSE
DEIF
SmartGen
FALAD POWER®
FAQ
How do I size a diesel or gas generator set, and what power range does FALAD POWER® manufacture?
To size a generator set, check the running load and the motor-starting condition separately: work out the total load at the moment your largest motor starts in consistent units, and choose a set whose rating and motor-starting capability cover it (VFD, soft-starter or Star-Delta starting lowers the starting demand). Allow a 20–25% reserve margin and account for site altitude (>1,000 m) and ambient temperature (>40 °C) derating per ISO 8528-1; our engineers confirm the calculation for your load list. Shandong Faraday Power Technology Co., Ltd. (FALAD POWER®) manufactures over 1,700 models covering 10–3750 kVA at 50 Hz (1500 rpm, 400/230 V up to 10.5 kV) and 60 Hz (1800 rpm, 208–480 V up to 13.8 kV). Send us your load list or single-line diagram for a free engineering sizing report.
What is the difference between Prime Power, Standby Power and Continuous Power?
ISO 8528-1 defines four ratings:
• Continuous Power (COP): constant load, unlimited running hours — for base-load plants running the same load around the clock.
• Prime Power (PRP): variable load, unlimited annual hours, average load no more than 70% over 24 hours, with 10% overload typically available for 1 hour in every 12 — for mines, construction sites and areas without grid power.
• Limited-Time Running Power (LTP): constant load for up to 500 hours a year, no overload.
• Emergency Standby Power (ESP): variable load during grid outages only, typically up to 200 hours a year, no overload — for hospitals, offices, data centers and factories that need grid backup.
Standby rating is about 10% higher than prime (for example, 500 kVA prime ≈ 550 kVA standby). Every FALAD POWER datasheet lists both prime and standby ratings. Tell us whether the set will be your main power source or a grid backup, and we will quote the right rating. All sets use pure copper brushless alternators from Stamford, Leroy-Somer, Mecc Alte, Marathon, Engga or FALAD POWER.