FALAD POWER generator sets lined up in the factory warehouse

Diesel Generator Sets Powered by Cummins

23–2000 kVA

  • CE / ISO
  • Certified OEM Factory
  • Global Warranty
Get a Quote

In-House Manufacturing

Our own production base covers genset R&D, manufacturing, assembly and testing under one roof.

Global Export

Shipped to 80+ countries, with experience in import regulations, port logistics and local certification.

Full-Load Testing

Every unit is load-tested before dispatch and ships with a detailed test report.

OEM

OEM Customization

Custom branding, canopy, configuration and functions — a one-stop OEM genset service.

Overview

Cummins supplies engines and power systems, including engines used in generator sets. This page features FALAD POWER generator sets powered by Cummins engines. Share your required power, voltage, frequency and destination to request a configuration and quote.

Select power (50 Hz) 85 models

Dongfeng Cummins (DCEC)

Chongqing Cummins (CCEC)

Cummins – China Stage III

Cummins – China Stage IV

Genset model: YXKMS18GF
Engine BrandCummins
Engine Model4B3.9-G11
Generator Set Prime Power (PRP)18 kW / 22.5 kVA
Generator Set Standby Power (ESP)20 kW / 25 kVA
Frequency / Rated Speed50 Hz / 1500 rpm
Fuel Consumption at 100% Load253 g/kWh
Overall Dimensions (L×W×H)1950 × 735 × 1420 mm
Total Weight765 kg

Brand Introduction

Cummins engine manufacturing

Founded in 1919, Cummins is a global power technology leader with 600 distribution locations and 7,500 dealer locations across 190 countries.

Core advantages

  • Established powertrain technology
  • Robust construction
  • Reliable power output
  • Optimized fuel efficiency
  • Global service support
  • 1919Founded
  • 190+Countries served
  • G-DriveGenset engines

Technical Parameters

Dongfeng Cummins (DCEC)

Dongfeng Cummins (DCEC) technical parameters, 50 Hz / 1500 rpm
Genset ModelPrime Power (kW / kVA)Standby Power (kW / kVA)Engine ModelDimensions L×W×H (mm)Weight (kg)
18 / 22.5 20 / 25 4B3.9-G11 1950×735×1420 765
20 / 25 22 / 27.5 4B3.9-G2 1950×735×1420 765
24 / 30 26 / 32.5 4B3.9-G12 1950×735×1420 765
30 / 37.5 33 / 41.3 4BT3.9-G2 1950×735×1420 765
40 / 50 45 / 56.3 4BTA3.9-G2 1950×735×1420 765
50 / 62.5 55 / 68.8 4BTA3.9-G11 2180×735×1450 830
64 / 80 70 / 87.5 4BTA3.9-G11 2180×735×1500 850
80 / 100 90 / 112.5 4BTA3.9-G13 2180×735×1500 850
90 / 112.5 100 / 125 4BTAA3.9-G3 2475×800×1470 1,185
100 / 125 110 / 137.5 6BTA5.9-G2 2620×800×1500 1,280
110 / 137.5 120 / 150 6BTAA5.9-G2 2620×800×1500 1,300
120 / 150 132 / 165 6BTAA5.9-G12 2620×800×1500 1,300
150 / 187.5 170 / 212.5 6CTA8.3-G2 2680×855×1560 1,600
160 / 200 180 / 225 6CTAA8.3-G2 2900×1045×1640 1,700
180 / 225 200 / 250 6CTAA8.3-G9 2900×1045×1780 1,900
200 / 250 220 / 275 6LTAA8.9-G2 2900×1045×1780 1,900
250 / 312.5 275 / 343.8 6LTAA9.5-G1 2900×1045×1780 2,000
280 / 350 300 / 375 QSZ10-G12 3400×1360×2000 3,220
300 / 375 300 / 375 QSZ10-G11 3400×1360×2000 3,220
350 / 437.5 385 / 481.3 6ZTAA13-G2 3400×1360×2010 3,220
360 / 450 400 / 500 QSZ13-G2 3400×1360×2010 3,220
400 / 500 450 / 562.5 QSZ13-G5 3400×1360×2010 3,220
400 / 500 450 / 562.5 QSZ13-G10 3420×1360×2010 3,220

Chongqing Cummins (CCEC)

Chongqing Cummins (CCEC) technical parameters, 50 Hz / 1500 rpm
Genset ModelPrime Power (kW / kVA)Standby Power (kW / kVA)Engine ModelDimensions L×W×H (mm)Weight (kg)
200 / 250 220 / 275 NT855-GA 3270×1150×1700 2,700
220 / 275 250 / 312.5 NTA855-G1A 3530×1150×1980 3,300
250 / 312.5 280 / 350 NTA855-G1B 3370×1500×1800 2,900
280 / 350 300 / 375 NTA855-G2A 3370×1050×1800 2,950
300 / 375 330 / 412.5 NTAA855-G7 3370×1050×1800 2,300
320 / 400 360 / 450 M15-G6 3550×1200×1960 2,800
360 / 450 400 / 500 M15-G7 3550×1200×1960 3,000
400 / 500 450 / 562.5 M15-G8 3700×1280×2100 4,300
450 / 562.5 500 / 625 KTA19-G8 3900×1750×2300 4,900
500 / 625 550 / 687.5 KTAA19-G6A 4060×1550×2240 4,700
580 / 725 640 / 800 KT38-GA 4350×1750×2200 6,600
600 / 750 660 / 825 KTA38-G2 4350×1750×2200 6,600
640 / 800 700 / 875 KTA38-G2B 4350×1750×2200 6,700
730 / 912.5 800 / 1000 KTA38-G2A 4350×1750×2200 6,850
800 / 1000 900 / 1125 KTA38-G5 4300×2100×2200 7,150
900 / 1125 1000 / 1250 KTA38-G9 4350×2100×2200 7,200
1000 / 1250 1100 / 1375 KTA50-G3 4960×2100×2350 9,150
1200 / 1500 1320 / 1650 KTA50-G8 5050×2260×2460 9,400
1350 / 1687.5 1500 / 1875 KTA50-G15X 5250×2150×2550 9,600
1600 / 2000 1800 / 2250 KTA50-G16B 5250×2150×2550 9,600

Cummins – China Stage III

Cummins – China Stage III technical parameters, 50 Hz / 1500 rpm
Genset ModelPrime Power (kW / kVA)Standby Power (kW / kVA)Engine ModelDimensions L×W×H (mm)Weight (kg)
20 / 25 22 / 27.5 QSB3.9-G31 1950×735×1420 765
30 / 37.5 33 / 41.3 QSB3.9-G33 1950×735×1420 765
50 / 62.5 55 / 68.8 QSB3.9-G35 2180×735×1450 830
60 / 75 66 / 82.5 QSB3.9-G2 2180×735×1450 830
70 / 87.5 80 / 100 QSB3.9-G3 2180×735×1500 850
80 / 100 88 / 110 QSB3.9-G37 2475×800×1470 1,185
90 / 112.5 100 / 125 QSB3.9-G39 2475×800×1470 1,185
100 / 125 110 / 137.5 QSB5.9-G3 2620×800×1500 1,300
120 / 150 132 / 165 QSB5.9-G31 2620×800×1500 1,300
130 / 162.5 150 / 187.5 QSB5.9-G33 2620×800×1500 1,300
150 / 187.5 165 / 206.3 QSB6.7-G32 2680×855×1560 1,600
180 / 225 200 / 250 QSB6.7-G31 2900×1045×1640 1,700
200 / 250 220 / 275 QSL8.9-G34 2900×1045×1780 1,900
250 / 312.5 275 / 343.8 QSL8.9-G33 2900×1045×1780 1,900
280 / 350 300 / 375 QSL8.9-G30 3370×1500×1800 2,900
300 / 375 330 / 412.5 QSM11-G5 3370×1050×1800 2,300
320 / 400 360 / 450 QSNT-G3 3550×1200×1960 2,800
360 / 450 400 / 500 QSNT-G4X 3700×1280×2100 4,300
450 / 562.5 500 / 625 KTA19-G8E 3900×1750×2300 4,900
500 / 625 550 / 687.5 KTA19-G8A 3900×1750×2300 4,900
550 / 687.5 600 / 750 KTA19-G9A 4060×1550×2240 4,700
600 / 750 660 / 825 QSK19-G33 4350×1750×2200 6,600
640 / 800 700 / 875 QSK19-G34 4350×1750×2200 6,700
730 / 912.5 800 / 1000 KTA38-G5E 5050×2260×2460 8,800
800 / 1000 900 / 1125 KTA38-G7E 5050×2260×2460 8,900
900 / 1125 1000 / 1250 KTA38-G9E 5050×2260×2460 9,000
1000 / 1250 1100 / 1375 KTA38-G9A 5050×2260×2460 9,200
1100 / 1375 1200 / 1500 KTA50-G7E 5050×2260×2460 9,400
1200 / 1500 1300 / 1625 KTA50-G8E 5050×2260×2460 9,400
1300 / 1625 1400 / 1750 QSK38-G32 5250×2150×2550 9,600
1350 / 1687.5 1500 / 1875 KTA50-G15A 5250×2150×2550 10,000
1500 / 1875 1650 / 2062.5 KTA50-G16A 5250×2150×2550 10,000

Cummins – China Stage IV

Cummins – China Stage IV technical parameters, 50 Hz / 1500 rpm
Genset ModelPrime Power (kW / kVA)Standby Power (kW / kVA)Engine ModelDimensions L×W×H (mm)Weight (kg)
40 / 50 44 / 55 B3.9CS4-GT3 1950×735×1420 765
50 / 62.5 55 / 68.8 B3.9CS4-GT2 2180×735×1450 830
60 / 75 66 / 82.5 B3.9CS4-GT1 2180×735×1500 850
75 / 93.8 83 / 103.8 B5.9CS4-GT3 2475×800×1470 1,185
100 / 125 110 / 137.5 B5.9CS4-GT2 2475×800×1470 1,185
110 / 137.5 121 / 151.3 B5.9CS4-GT1 2620×800×1500 1,300
130 / 162.5 143 / 178.8 B6.7CS4-GT2 2680×855×1560 1,600
150 / 187.5 165 / 206.3 B6.7CS4-GT1 2680×855×1560 1,600
200 / 250 220 / 275 L9CS4-GT2 2900×1045×1780 1,900
220 / 275 250 / 312.5 L9CS4-GT1 2900×1045×1780 1,900

Data at 50 Hz, 1500 rpm, 400 V, 0.8 power factor (lagging), three-phase four-wire. 60 Hz ratings, other voltages and custom configurations are available — ask for a full datasheet.

Product Advantages & Core Configuration

Factory tested
  • Diesel engine for a generator set

    Officially Authorized

    Genuine engines from multiple brands

  • Generator set digital controller

    Intelligent Protection

    Remote monitoring and control

  • Brushless alternator

    Flexible Options

    Configured to your requirements

Accessories

  • Branded electrical components, switches and meters

    Branded Electrical Components

  • Maintenance-free starter battery

    Camel / VARTA Maintenance-Free Battery

  • Cloud remote monitoring module

    Cloud Monitoring Module

  • Engine oil and water jacket heater

    Oil & Water Jacket Heater

Weifang Yuxing Power Co., Ltd. manufacturing base of FALAD POWER generator sets in Weifang, Shandong

Why Choose Us

  • Industry Experience

    Proven genset R&D and manufacturing expertise, with project references worldwide.

  • Global Supply

    Exported to many countries; we know local standards and supply reliably.

  • Strict Testing

    Every set is inspected and run-tested for stable, long-term operation.

  • Flexible Configuration

    Engine, alternator and controller brands are combined to suit each application.

  • Fast Response

    A mature production line and supply chain ensure on-time delivery and lower project risk.

  • Technical Support

    Sizing, installation, commissioning and after-sales technical support.

Generator production workshop

300,000+

Total units sold

Aerial view of the factory campus

60,449 m²

Factory area

Factory building exterior

8,000+

Partner service points

Intelligent generator test center

Full-load

Test report for every unit

From Our Factory to Your Site

  • Gas generator sets running a biogas power project

    Biogas Projects

  • Containerized power station at an oil field

    Oil & Gas Fields

  • Natural gas generator containers in a row

    Natural Gas Projects

  • Generator set at a remote telecom tower

    Telecom Base Stations

  • Generator being installed on a construction site

    Construction

  • Standby diesel generators in a data center

    Data Centers

  • Engineers commissioning hospital backup power panels

    Hospital Backup Power

  • Alternator assembly workshop

    Alternator Assembly Workshop

  • Diesel genset assembly workshop

    Genset Assembly Workshop

  • Silent generator sets for factory standby power

    Factory Standby Power

  • Trailer generator sets for a mining project

    Mining Projects

  • Generator sets loaded on a truck for delivery

    Project Logistics

Brand Partners

Engine partners

  • Perkins logoPerkins
  • Cummins logoCummins
  • Volvo Penta logoVolvo Penta
  • DEUTZ logoDEUTZ
  • Scania logoScania
  • FPT logoFPT
  • Isuzu logoIsuzu
  • MTU logoMTU
  • Kubota logoKubota
  • Hyundai (Doosan) logoHyundai (Doosan)
  • Baudouin logoBaudouin
  • Weichai logoWeichai
  • Yuchai logoYuchai
  • SDEC logoSDEC
  • FAWDE logoFAWDE
  • Yunnei logoYunnei
  • Yangdong logoYangdong
  • YUXING logo – Weifang Yuxing Power Co., Ltd.YUXING

Alternator partners

  • Stamford logoStamford
  • Leroy-Somer logoLeroy-Somer
  • Mecc Alte logoMecc Alte
  • Engga logoEngga
  • FALAD POWER® (Faraday) alternator – own brand of Shandong Faraday Power Technology Co., Ltd.FALAD POWER®

Controller partners

  • ComAp logoComAp
  • DSE logoDSE
  • DEIF logoDEIF
  • SmartGen logoSmartGen
  • FALAD POWER® controller – own brand of Shandong Faraday Power Technology Co., Ltd.FALAD POWER®

FAQ

How do I size a diesel or gas generator set, and what power range does FALAD POWER® manufacture?

To size a generator set, check the running load and the motor-starting condition separately: work out the total load at the moment your largest motor starts in consistent units, and choose a set whose rating and motor-starting capability cover it (VFD, soft-starter or Star-Delta starting lowers the starting demand). Allow a 20–25% reserve margin and account for site altitude (>1,000 m) and ambient temperature (>40 °C) derating per ISO 8528-1; our engineers confirm the calculation for your load list. Shandong Faraday Power Technology Co., Ltd. (FALAD POWER®) manufactures over 1,700 models covering 10–3750 kVA at 50 Hz (1500 rpm, 400/230 V up to 10.5 kV) and 60 Hz (1800 rpm, 208–480 V up to 13.8 kV). Send us your load list or single-line diagram for a free engineering sizing report.

What is the difference between Prime Power, Standby Power and Continuous Power?

ISO 8528-1 defines four ratings:
• Continuous Power (COP): constant load, unlimited running hours — for base-load plants running the same load around the clock.
• Prime Power (PRP): variable load, unlimited annual hours, average load no more than 70% over 24 hours, with 10% overload typically available for 1 hour in every 12 — for mines, construction sites and areas without grid power.
• Limited-Time Running Power (LTP): constant load for up to 500 hours a year, no overload.
• Emergency Standby Power (ESP): variable load during grid outages only, typically up to 200 hours a year, no overload — for hospitals, offices, data centers and factories that need grid backup.
Standby rating is about 10% higher than prime (for example, 500 kVA prime ≈ 550 kVA standby). Every FALAD POWER datasheet lists both prime and standby ratings. Tell us whether the set will be your main power source or a grid backup, and we will quote the right rating. All sets use pure copper brushless alternators from Stamford, Leroy-Somer, Mecc Alte, Marathon, Engga or FALAD POWER.

Get a Quote

I would like

* Please provide either your Email address or WhatsApp number so our engineers can send your quotation within 24 hours.

We reply within 24 hours. Your details are used only to answer your enquiry – see our Privacy Policy.

WhatsApp Email Get a Quote